System

 

Cisco MDS 9000 Series Multilayer Switches. Specifically seen in MDS 9148

 

Software Versions 


Currently known influential versions are 8.1(1) and 8.2(1)


Issue


MDS9148S shows intermittent ChassisFan failures and absurdly high SFP temperature alarms. 

The following logs combination is found in show logging log (SFP temperature and ChassisFan can vary):


Description


2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '1' reported temperature alarm. SFP temperature = '1274 C', threshold '78 C' - lc_port_cfg

2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '2' reported temperature alarm. SFP temperature = '1275 C', threshold '78 C' - lc_port_cfg

2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '3' reported temperature alarm. SFP temperature = '1274 C', threshold '78 C' - lc_port_cfg

2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '7' reported temperature alarm. SFP temperature = '1275 C', threshold '78 C' - lc_port_cfg

2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '8' reported temperature alarm. SFP temperature = '1275 C', threshold '78 C' - lc_port_cfg

2019 Apr 11 11:05:41 SW1-UP %USER-3-SYSTEM_MSG: lc_port_cfg: (line 609):SFP in port '9' reported temperature alarm. SFP temperature = '1275 C', threshold '78 C' - lc_port_cfg


Important Note: This is not harmful to the system, transceivers, or fans. These are false alarms that are displayed and by viewing the DOM details you can still see the true temperature values:


    SFP Diagnostics Information:

----------------------------------------------------------------------------

                                     Alarms                  Warnings

                                High        Low         High          Low

----------------------------------------------------------------------------

  Temperature   34.01 C         90.00 C    -10.00 C     85.00 C       -5.00 C

  Voltage        3.31 V          3.63 V      2.97 V      3.46 V        3.13 V

  Current        7.24 mA        15.00 mA     1.00 mA    12.00 mA       2.00 mA

  Tx Power      -2.27 dBm        0.79 dBm   -7.97 dBm    0.00 dBm     -7.00 dBm

  Rx Power      -2.99 dBm        3.01 dBm  -16.02 dBm    0.00 dBm    -13.00 dBm   

  Transmit Fault Count = 0

----------------------------------------------------------------------------

  Note: ++  high-alarm; +  high-warning; --  low-alarm; -  low-warning



Solution

 

Reloading the switch has been reported to temporarily resolve this issue.


Recommend updating the software version to another stable build

 

Sources


https://quickview.cloudapps.cisco.com/quickview/bug/CSCvn66653